Fracturas complejas del radio distaltratamiento quirúrgico de las fracturas tipo C2
- Arenas Planelles, Antonio
- Ortega Arruti, J.A.
- Corchuelo Maíllo, C.
- Arenas Miquélez, Antonio
- Ortega Sáez, M.
ISSN: 0304-5056
Datum der Publikation: 2007
Ausgabe: 42
Nummer: 231
Seiten: 102-112
Art: Artikel
Andere Publikationen in: Revista española de cirugía osteoarticular
Zusammenfassung
A total of 73 cases of C2 type fracture of the distal radius treated in our Department are presented. A volar pla- te was used as fixation method in 3 cases, Kirschner wire in 38 cases, external fixator in 30 cases, and external fixator plus Kirschner wire in 2 cases. The best results were obtai- ned in the groups of cases treated with a volar plate and ex- ternal fixator associated with Kirschner wire. The isolated external fixator, that at first was the best system of treatment, has turned out to be the procedure that has been accompa- nied by a greater incidence of clinical sequels and vicious consolidations.