Medición de presión intraocular con el tonómetro Proview®
ISSN: 0365-6691
Year of publication: 2005
Volume: 80
Issue: 2
Pages: 79-83
Type: Article
More publications in: Archivos de la Sociedad Española de Oftalmologia
Abstract
Purpose: To evaluate a new ocular tonometer (Proview®) which functions by visualizing a phosphene after putting pressure on the upper eyelid. To ascertain its accuracy and reproducibility with respect to the Goldmann tonometer (GT). Methods: A study on both eyes of 110 non-selected patients was performed. One measurement with GT and three subsequent measurements with Proview® were taken by the same investigator. The number of failed attempts to visualize the phosphene was recorded. We evaluated each eye separately to observe the possible learning effect. Results: The intraocular pressure (IOP) mean with Proview® is 5 mm Hg higher than the GT (p<0.001). The coefficient of correlation between both instruments is low (R = 0.67; R²=0.45) in the right eye (RE). The difference between maximum and minimum values of the 3 measurements taken with the Proview® was 3.21 (SD: 1.73) mm Hg in RE. The failed attempts to see the phosphene were 5.14 (SD: 2.39) in RE and 4.93 (SD: 2.78) in left eye (p>0.05). Conclusions: The Proview® tonometer showed low accuracy and reproducibility in comparison with the GT. This tonometer requires a long learning process before phosphene visualization. The results demonstrated that this tonometer is not clinically useful, except in patients with serious corneal diseases which make measurement with GT very difficult.
Bibliographic References
- Damji, KF, Muni, RH, Munger, RM. (2003). Influence of corneal variables on accuracy of intraocular pressure measurement. J Glaucoma. 12. 69-80
- Fresco, BB. (1998). A new tonometer- the pressure phosphene tonometer: clinical comparison with Goldmann tonometry. Ophthalmology. 105. 2123-2126
- Lam, DS, Leung, DY, Chiu, TY, Fan, DS, Cheung, EY, Wong, TY. (2004). Pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients. Invest Ophthalmol Vis Sci. 45. 3131-3136
- Álvarez, TL, Gollance, SA, Thomas, GA, Greene, RJ, Marchetto, PM, Moore, EJ. (2004). The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice. Ophthalmology. 111. 1077-1085
- Danesh-Meyer, HV, Niederer, R, Gaskin, BJ, Gamble, G. (2004). Comparison of the Proview pressure phosphene tonometer performed by the patient and examiner with the Goldmann applanation tonometer. Clin Experiment Ophthalmol. 32. 29-32
- Li, J, Herndon, LW, Asrani, SG, Stinnett, S, Allingham, RR. (2004). Clinical comparison of the proview eye pressure monitor with the Goldmann applanation tonometer and the TonoPen. Arch Ophthalmol. 122. 1117-1121
- Kao, SF, Lichter, PR, Bergstrom, TJ, Rowe, S, Musch, DC. (1987). Clinical comparison of the Oculab tono-pen to the Goldmann applanation tonometer. Ophthalmology. 94. 1541-1544